Diesel engine fire pumps are being boxed and shipped to Manila, Philippines!

Nov 23, 2022
Share:
In the actual operation process, we have summarized the following three ventilation methods, let's talk about them in detail.
1. Natural ventilation: When setting up and arranging diesel engine fire pumps, it is first necessary to consider adequately sized ventilation openings and exhaust openings, and secondly, to ensure that there is enough fresh air to supply diesel engine combustion within the temperature limit. In this way, the heat of the circulating cooling water can be taken away by the water supply radiator to take away the heat radiated from the surface of the unit.

2. Forced ventilation: when the natural ventilation conditions cannot be met, forced ventilation can be adopted. Inlet fans and exhaust fans can be installed at the vents. The fan specifications and the location of the air inlet and outlet in the engine room should be selected to provide enough cold air for the diesel engine. At the same time, the hot air in the pump room is taken away, and the small air intake volume of the unit needs to be about 6-7 times that of the diesel engine air intake.

3. Arrange grooves and sewers: By arranging sewers around the unit foundation and arranging mountain grooves in the middle of the unit foundation, the purpose of this is to facilitate the flushing of sewage and diesel oil, thereby ensuring the sanitation of the pump room. Therefore, purchasing a diesel engine fire pump is not only a simple act of "buying", but also considers the placement of the equipment, whether there is a pump room, and the subsequent operating conditions. Of course, professional fire pump manufacturers, such as zjbetter, etc., in addition to product supply, will also provide customers with targeted, reliable and safe suggestions in these aspects. In addition, before and after each use of the diesel engine fire pump, pay attention to check the connection status of each mechanism of the fire pump group, such as whether the rotating part is flexible, etc., to ensure that each oil circuit, circuit and instrument joints are firm and reliable, and the circuit is not loose. . In addition, before starting the engine, pay attention to check the starting performance of the engine. In order to ensure that there is no failure every time the engine is started, it is necessary to pump water for a certain period of time after idling every week, so as to ensure the reliability of the entire control system. Doing so can ensure safe use on the one hand, and harmless use on the other hand.

Inquiry
If you are interested in our products or have some questions, email us, we will contact you as soon as possible.
Name *
Country
Email *
Tel
Flow
Head
Message *
WhatsApp me